Applications
The special robot cable for the robot arm is suitable for this special cable as the transmission of control and monitoring signals and the power connection. It is suitable for installation in various occasions where torsion and bending stress exist at the same time. The high-quality insulation and non-slip non-square cloth wrapper make the The robot cable is suitable for life extension under the condition that torsion and bending stress exist at the same time. The working voltage is 12V-750V, and the ambient temperature is -60~80℃. The connecting cable for the robot arm of the robot arm is suitable for automobiles manufacturing, metallurgy, coal mine, machine tool, equipment processing, high-risk operations and other workplaces. The product has the characteristics of heat radiation, cold resistance, acid and alkali resistance and corrosive gas, waterproof, etc. The cable structure is soft, easy to install, stable electrical performance in high temperature (alpine) environment, outstanding anti-aging performance, and long service life.
In the cable/pipe package of the crank arm robot, as well as the gantry robot, it is used in the automotive industry for power drag chains or mechanical moving parts automation equipment.
Product structure
Conductor: multiple strands of thin bare copper wires are bundled with soft structure conductors, which should be stranded first and then stranded
Insulation: TPE
Cable formation: stranded core wires
Center: The cable has an additional center pair: 2 core wires are twisted and wrapped with PTFE aluminum foil, and the surface is shielded with tin copper wire (optional)
Inner protection material: imported special materials for mixed sheath
Outer sheath: The sheath adopts high-tear-resistant imported brand PUR material extrusion process, the purpose is to fully fill the gap of the cable core with the rubber material to make the cable dense.
Technical Parameters
Operating temperature: fixed installation: -50°C to +80°C (UL/CSA: +80°C)
mobiles installation: -45°C to +80°C (UL/CSA: +80°C)
Bending radius
mobiles installation: 6.5 × outer diameter
Fixed installation: 4 x outer diameter
Rated voltage:
IEC U0/U: 450/750 V
UL/CSA: 600 V
Test cable: 3000V
Burning test: flame retardant, in line with IEC 60332-1-2,
UL VW-1, cable burning test, CSA FT 1
Non-flammable, in line with IEC 60332-3-22 Class A standard
Core wire identification: color core wire identification, in line with VDE 0293-308
6 cores and above: black cores and white numbers
Torsion resistance: torsion meets the maximum ± 360 °/m
Inductance: about 0.7 mH/km
Mutual capacitance: core / core: about 100 nF/km
Core/screen about 120 nF/km
Certification standards
American Standard: UL